Mechanical pressure and temperature switches perform sensitive tasks in safety-relevant applications, e.g. monitoring limit values. Their functional safety must be guaranteed accordingly. That is always the case if the instruments fulfil the requirements of the corresponding safety integrity level (SIL) in accordance with the IEC 61508 standard. WIKA switches have been issued SIL approval because of their proven operational reliability.
Types of WIKA switches whose functional safety is SIL-certified: a concise temperature switch with Ex d flameproof enclosure (model TCA; left), a Bourdon tube pressure switch (model BA/BAX; top right) and a miniature pressure switch (model PXS; bottom right).
Hazards to people, the environment and the plant that can emanate from critical processes must therefore be reduced to an acceptable minimum. IEC 61508 supplies the necessary specifications for this. These are defined in various safety integrity levels, SIL 1 to 4.
The typical places equal responsibility on the responsible process developers and the manufacturers of the necessary components. For every instrument, it defines limit values for the likelihood of failure of a safety-relevant function. At the same time, it provides criteria for the possibility of controlling and avoiding systematic errors.
When the topic of ?functional safety? is discussed in expert groups regarding the SIL approval, it really is mainly concerning electrical systems. However, numerous mechanical components are also integrated within safety-relevant applications. These include measuring instruments that do not want external power and therefore work reliably, even in the event of an electrical failure. A SIL approval for these does mean a clear statement on functional safety. Regarding mechanical parts, it really is primarily a question of the consequences of aging and wear.
Individually installed: SIL 2, combined redundantly: SIL 3
The SIL certificate for WIKA?s pressure and temperature switches was issued in 2019 by exida, a globally recognised testing company. According to its assessment, the instruments, when installed individually, meet up with the requirements of SIL 2, and in redundant combination, they even meet those of the level SIL 3.
Two routes to assessment
In addition to the actual classification, the certificate for the WIKA switches also includes the addition ?route 2H?. In principle, you can find two ways to reach a SIL assessment: ?Route 1H? states that the instruments or components in question have been developed and manufactured in accordance with the respective SIL specifications. ?Route 2H?, on the other hand, confirms that the assessment was additionally based on their operational reliability, as regarding WIKA switches. ไดอะแฟรม certified error rate is calculated from data collected during used in a credit card applicatoin in the field and transmitted to exida. The SIL assessment of functional safety is thus completed on an authentic basis: For each element of a device, at least 100 million operating hours will need to have been proven.
Empirical values in a database
The SIL assessment in accordance with route 2H refers to the empirical values from field use, which are stored in an exida database. There, specific operating conditions such as for example temperature, vibration etc. are taken into account.
Note
Detailed home elevators switches with SIL certificate ? pressure switches of the M, B, A, D, PC and PX series along with temperature switches of the T series ? can be found on the WIKA website. The approval certificate is also available as a PDF file there. In case you have any further questions, your contact will gladly assist you to.
Also read our articles
SIL pressure switch: Safety in tyre manufacturing